Mitsubishi Electronics MR-J2S- CL User Manual

Page of 337
5 -  25
5. PARAMETERS
5.2.5 Changing the stop pattern using a limit switch
The servo amplifier is factory-set to make a sudden stop when the limit switch or software limit is made
valid. When a sudden stop is not required, e.g. when there is an allowance from the limit switch
installation position to the permissible moving range of the machine, a slow stop may be selected by
changing the parameter No.22 setting.
Parameter No. 22 setting
Description
     0 (initial value)
Droop pulses are reset to make a stop. (Sudden stop)
     1
Droop pulses are drawn out to make a slow stop. (Slow stop)
5.2.6 Alarm history clear
The alarm history can be confirmed by using the Set-up Software or communication function. The servo
amplifier stores one current alarm and five past alarms from when its power is switched on first. To
control alarms which will occur during operation, clear the alarm history using parameter No.16 (alarm
history clear) before starting operation. Clearing the alarm history automatically returns to “     0   ”.
This parameter is made valid by switching power off, then on after setting.
Alarm history clear
0: Invalid (not cleared)
1: Valid (cleared)
Parameter No. 16
5.2.7 Software limit
A limit stop using a software limit is made as in stroke end operation. When a motion goes beyond the
setting range, the motor is stopped and servo-locked. This function is made valid at power-on but made
invalid during home position return. This function is made invalid when the software limit   setting is
the same as the software limit   setting. A parameter error (AL. 37) will occur if the software limit 
setting is less than the software limit   setting.
Current position
Unmovable
Movable
Movable area
Software limit
Inhibited area