8. GENERAL GAIN ADJUSTMENT
8.5 Differences in auto tuning between MELSERVO-J2 and MELSERVO-J2-Super
8.5.1 Response level setting
To meet higher response demands, the MELSERVO-J2-Super series has been changed in response level
setting range from the MELSERVO-J2 series. The following table lists comparison of the response level
setting.
Response level setting
Parameter No. 3
MELSERVO-J2 series
MELSERVO-J2-Super series
Response level setting
Machine resonance frequency
Response level setting
Machine resonance frequency guideline
1
15Hz
1
20Hz
2
20Hz
3
25Hz
4
30Hz
5
35Hz
2
40Hz
6
45Hz
7
55Hz
3
60Hz
8
70Hz
4
80Hz
9
85Hz
5
100Hz
A
105Hz
B
130Hz
C
160Hz
D
200Hz
E
240Hz
F
300Hz
Note that because of a slight difference in gain adjustment pattern, response may not be the same if the
resonance frequency is set to the same value.
8.5.2 Auto tuning selection
The MELSERVO-J2-Super series has an addition of the load inertia moment ratio fixing mode. It also has
the addition of the manual mode 1 which permits manual adjustment with three parameters.
Parameter No. 3
Auto tuning selection
Auto tuning selection
Gain adjustment mode
MELSERVO-J2 series
MELSERVO-J2-Super series
Remarks
Interpolation mode
0
0
Position control gain 1 is fixed.
Auto tuning mode 1
1
1
Ordinary auto tuning
Auto tuning
Auto tuning mode 2
2
Estimation of load inertia moment
ratio stopped.
Response level setting valid.
Manual mode 1
3
Simple manual adjustment
Auto tuning
invalid
Manual mode 2
2
4
Manual adjustment of all gains