14. OPTIONS AND AUXILIARY EQUIPMENT
14.2.8 EMC filter
For compliance with the EMC Directive of the EN Standard, it is recommended to use the following filter:
Some EMC filters are large in leakage current.
(1) Combination with the servo amplifier
Recommended filter
Servo amplifier
Model
Leakage current [mA]
Weight [kg]([lb])
MR-J2S-10CL to MR-J2S-100CL
MR-J2S-10CL1 to MR-J2S-40CL1
SF1252
38
0.75 (1.65)
MR-J2S-200CL MR-J2S-350CL
SF1253
57
1.37 (1.65)
MR-J2S-500CL
(Note)
 HF-3040A-TM
1.5
5.5 (12.13)
MR-J2S-700CL
(Note)
 HF-3050A-TM
1.5
6.7 (14.77)
Note : Soshin Electric. A surge protector is separately required to use any of these EMC filters. (Refer to the EMC Installation
Guidelines.)
(2) Connection example
NFB
L
1
L
2
L
3
L
11
L
21
L
1
L
2
L
3
LINE
LOAD
3-phase 
200 to 230V AC, 
1-phase 
230VAC or
1-phase 
 100 to120VAC 
EMC filter
Servo amplifier
(Note 1) Power supply
(Note 2)
Note: 1. For 1-phase 230VAC power supply, connect the power supply to L
1
,L
2
 and leave L
3
 open.
              There is no L
3
 for 1-phase 100 to 120VAC power supply.
          2. Connect when the power supply has earth.
L
1
L
2
L
3
(3) Outline drawing
23.0(0.906)
LAB
E
L
LI
N
E
LOA
D
16
8.0(
6
.6
1
4
)
L1'
L2'
L3'
L1
L2
L3
149.5(5.886)
LINE
(input side)
LOAD
(output side)
14
0.0(
5
.5
1
2
)
15
6.0(
6
.1
4
2
)
16.0(0.63)
42.0
8.5
SF1252
LAB
E
L
LI
N
E
LOA
D
16
8.0(
6
.6
1
4
)
L1'
L2'
L3'
L1
L2
L3
209.5(8.248)
LINE
(input side)
LOAD
(output side)
14
0.0(
5
.5
1
2
)
15
6.0(
6
.1
4
2
)
49.0
8.5
SF1253
[Unit: mm(in)]
(0.335)
(1.654)
(0.335)
(1.929)
  6.0(0.236)
  6.0(0.236)