Mitsubishi Electronics MR-J2S- CL User Manual

Page of 337
3 -  15
3. SIGNALS AND WIRING
3.4.3 Override
POINT
When using the override (VC), make the override selection (OVR) device
available.
The override (VC) may be used to change the servo motor speed. The following table lists the signals and
parameter related to the override:
Item
Name
Remarks
Analog input signal
Override (VC)
Contact input signal
Override selection (OVR)
Servo Configuration Software setting required.
Parameter
No.25 override offset
999 to 999mV
(1) Override (VC)
By applying a voltage ( 10 to  10V) to the override (VC) terminal, change values can be set from
outside consecutively. The following graph shows the relationship between the input voltage and the
ratio of actual speed to preset speed.
Override selection (OVR)
OVR
SG
VC
LG
Servo amplifier
Override (VC)
Override (VC) application voltage
Rat
io o
f a
c
tual
 s
peed 
to
 
preset
 spe
e
d
10
10
200
[%]
0
[V]
0
100
SD
10 to   10V
(2) Override selection (OVR)
Used to make the override (VC) valid or invalid.
Servo amplifier
Override selection
(OVR)
Ov
er
ri
de
Override (VC)
   10 to  10V
Motor
Using the override selection (OVR), choose a change value as follows:
External input signal
OVR
Speed change value
0
No change
1
Override (VC) setting is made valid.
Note. 0 : OFF
1 : ON
(3) Override offset (parameter No.25)
Using parameter No.25, the offset voltage can be set relative to the input voltage for the override (VC).
The setting is between  999 to 999mV.