Emotiva MPS-1 User Manual

Page of 37
Page 14
Page 15
Turn On Selector Switch
This switch allows you to select how the 
amplifier will turn on and off. 
In the ON (Up) position, the switch on the 
front  of  the  amplifier  is  the  method  you 
will use to power up and power down the 
amplifier. Please note that in this configu-
ration, you must manually power up and 
power down the amplifier each time you 
use it or it will have unnecessary standby 
current draw.
In the SIGNAL (Middle) position, the am-
plifier automatically turns on whenever it 
senses an audio signal on any one of the 
seven amplifier channels. The circuit stays 
active for a full minute after the absence of 
any audio signal to account for quiet pas-
sages of music or dialogue.
In the TRIGGER (Down) position, the ampli-
fier’s ON and OFF functions are controlled 
by a trigger from a source or preamplifier 
device. The trigger accepts 12 VDC and will 
turn the amplifier on whenever a trigger is 
present  (See #5). When there is no trigger, 
the amplifier goes into standby mode. This 
is the preferred method for activating the 
MPS-1.
External Trigger Connection
This  external  trigger  connection  allows 
the amplifier to be turned ON and OFF by 
a control device such as a source unit or 
preamplifier. It can also be used with most 
home automation controllers. The trigger 
requires a 12 VDC trigger. This is the pre-
ferred method of activating the MPS-1. See 
page 23 for connection details.
Fuse #1
This fuse is for the power supply of the MPS-
1 chassis. It is a TL15AL type rated a 15A, 250 
V. If the fuse ever fails, be sure to replace it 
with the same type and rated fuse.
Fuse #2
This  fuse  is  also  for  the  power  supply  of 
the MPS-1 chassis. It is a TL15AL type rated 
a 15A, 250 V. If the fuse ever fails, be sure 
to replace it with the same type and rated 
fuse.
IEC Line Cord Socket
The MPS-1 comes with a detachable line 
cord  which  connects  here.  Plug  the  line 
cord into an AC wall socket which is cor-
rectly  configured  with  the  voltage  and 
current supply specified for the MPS-1. Do 
not plug this line cord into a power strip, 
it must plug directly into a wall socket. For 
more details on AC power considerations, 
see page 19.
Turn On Selector Switch
External  Trigger 
Connection
5
6
7
4
8