Crown 1201 User Manual

Page of 28
Micro-Tech Series Power Amplifiers
page 20
Operation Manual
Performance
MT-600
MT-1200
MT-2400
Voltage Gain (at maximum level setting, ± 0.5 dB)
      26dB sensitivitiy
      0.775V sensitivity
      1.4V sensitivity
26 dB
35.0 dB
30.0 dB
26 dB
36.0 dB
31.0 dB
26 dB
38.0 dB
33.0 dB
Required AC Mains
50/60 Hz, 100 - 240 VAC (±10%)
50/60 Hz, 100 - 240 VAC (±10%)
50/60 Hz, 100 - 240 VAC (±10%)
Power Draw at Idle
90 watts
90 watts
90 watts
Cooling
Flow-through ventilation from front to side
panels. Internal heat sinks with forced air
 cooling.
Flow-through ventilation from front to side
panels. Internal heat sinks with forced air
 cooling.
Flow-through ventilation from front to side
panels. Internal heat sinks with forced air
 cooling.
Dimensions: Width, Height, Depth
EIA Standard 19 in. x 3.5 in. (8.9cm) 
x 16 in. (40.6 cm)
EIA Standard 19 in. x 3.5 in. (8.9cm) 
x 16 in. (40.6 cm)
EIA Standard 19 in. x 3.5 in. (8.9cm) 
x 16 in. (40.6 cm)
Weight (120VAC, 60-Hz units)
       Net Weight
       Shippping Weight
36 lb 4 oz (16.5 kg)
41 lb 2 oz (18.7 kg)
41 lb 1 oz (18.6 kg)
45 lb 3 oz  (20.5 kg)
46 lb 14 oz (21.3 kg)
55 lb 12 oz (25.3 kg)
Weight (International units)
       Net Weight
       Shipping Weight
38 lb 7 oz (17.9 kg)
44 lb 2 oz (20.0 kg)
41 lb 0 oz (18.6 kg)
45 lb 4 oz (20.5 kg)
47 lb 9 oz (21.6 kg)
56 lb 6 oz (25.6 kg)
8 Specifications