XP7000/XP5000/XP3500/XP2500/XP1000 Owner’s Manual
Troubleshooting
The following table lists the main causes of abnormal operation and the corrective measures required as well as the protec-
tive circuit operation in each case.
● XP3500, XP2500
● XP7000, XP5000
Indicator(s)
Possible Cause
Remedy
Protection Circuit
CLIP indicator lights.
There is a short at a speaker ter-
minal, amplifier terminal, or wire.
Locate and correct the cause of 
the short.
The PC limiter circuit 
operates to protect the 
power transistors.
The amplifier load is excessive.
Use a speaker system with an 
impedance of at least 4 
Ω (STE-
REO/PARALLEL mode) or 8 
Ω 
(BRIDGE mode).
TEMP indicator lights.
The heat sink temperature has 
exceeded 85°C (185°F).
Check the ventilation slots, and 
provide better airflow around the 
amplifier.
The TEMP indicator 
lights up to indicate tem-
perature warning.
PROTECTION indica-
tor lights.
The heat sink temperature has 
exceeded 90°C (194°F).
Check the amplifier ventilation 
conditions and take appropriate 
measures to improve the airflow 
around the amplifier.
The thermal protection 
circuit operates to protect 
the power transistors.
Indicator(s)
Possible Cause
Remedy
Protection Circuit
PROTECTION indica-
tor lights.
A DC voltage of +2 V/-2 V or 
greater was generated in the 
power amplifier’s output circuit.
Consult your dealer or the near-
est Yamaha service center. 
The relay operates to 
protect the speaker sys-
tem.
Indicator(s)
Possible Cause
Remedy
Protection Circuit
Power has been shut 
down. (All indicators 
are off.)
A DC voltage of +2 V/-2 V or 
greater was generated in the 
power amplifier’s output circuit.
Consult your dealer or the near-
est Yamaha service center.
The protection circuitry 
shut off the power to pro-
tect the speaker system.