Lucent Technologies 585-210-940 User Manual

Page of 106
 
 
Maintaining Mirrored Systems 
CentreVu CMS Release 3 Version 8 Disk-Mirrored Systems
Replacing a faulty disk
69
Replacing a faulty disk
3
This section explains how to replace a faulty disk. The system does not 
need to be powered off or rebooted to perform this procedure.
Step 1: Identify the 
faulty disk
3
A disk problem is usually indicated in the
 /var/adm/messages file. The 
following lines, for example, indicate a disk problem: 
Those lines, however, do not tell us which disk has the problem. One way 
of finding out is to enter an
 ls -l /dev/dsk/c* 
command and 
search the output for a device description matching that in the warning 
message. For example:
That the ”/iommu@0....” information matches the same information in the 
warning message indicates that disk c0t2d0 is the faulty disk.
Jun 12 16:27:08 leopard unix: WARNING: 
Jun 12 16:27:08 leopard unix: Error for command 
’read(10)’ Error Level: R
Jun 12 16:27:09 leopard unix: retryable
Jun 12 16:27:09 leopard unix: Requested Block 0, 
Error Block: 0
Jun 12 16:27:09 leopard unix: Sense Key: Media Error
Jun 12 16:27:09 leopard unix: Vendor ’SEAGATE’:
Jun 12 16:27:09 leopard unix: ASC = 0x31 (medium 
format corrupted), ASCQ
= 0x0, FRU = 0x9
Jun 12 16:27:09 leopard unix: WARNING: 
/sbus@3,0/SUNW,fas@3,8800000/sd@2,0
#
ls
-l
/dev/dsk/c*
.
.
.
lrwxrwxrwx   1 root     root          50 Apr 24 15:21 
/dev/dsk/c0t2d0s0 -> ../../devices/sbus@3,0/SUNW,fas 
@3,8800000/sd@2,0:a
lrwxrwxrwx   1 root     root          50 Apr 24 15:21 
/dev/dsk/c0t2d0s1 -> ../../devices/sbus@3,0/SUNW,fas 
@3,8800000/sd@2,0:b
.
.
.
#