Lucent Technologies 585-210-940 User Manual

Page of 106
 
 
Troubleshooting 
CentreVu CMS Release 3 Version 8 Disk-Mirrored Systems
Error messages
89
Message:
component is attached
metattach: 
hostname: d21: growing of 
metadevice delayed
Explanation: Submirrors are out of sync.
Response:
Enter the command:
metasync
d21
This command effectively resyncs submirrors. 
Message:
device: 
devicename
cannot be setup or does 
not exist
Explanation: The device named is a CD-ROM drive or is not available 
and will not be used in the 
Solstice DiskSuite setup.
Response:
Verify that the device should not be used. 
Message:
device: 
devicename
will not be used
Explanation: The device named is a CD-ROM drive or is not available 
and will not be used in the 
Solstice DiskSuite setup.
Response:
If the device is c0t6d0, it is a CD-ROM drive and no 
further action is required. If the device is a disk, verify the 
sanity of the message: check device availability, for 
example, or use a 
format
 command to view partition 
sizes, etc. 
Message:
disk 
diskname already setup, exiting...
Explanation: You are trying to attach a disk that is already attached or 
is part of the base configuration. No response is 
necessary.
Message:
disk: 
diskname slice 1 is not partitioned 
correctly
Explanation: Disk is partitioned incorrectly, or the 
olds script was run 
without the 
-mirrored option.
Response:
Try rerunning the command with the -mirrored option. If 
that doesn’t work, repartition the disk.
If 
diskname is the primary boot disk, you must reload 
Solaris, repartitioning the disk correctly in the process. If 
diskname is not the primary boot disk, you can repartition 
it with the 
Solaris 
format
 command.
Error Messages (Continued)