JBL SDEC-3000 User Manual

Page of 24
 
- 20 - 
SDEC -X000 DACS Calibration Manual v1.0.doc 
 
10.2.1 
Parametric Filter Values  
 
Figure 20. 
11 Saving Your Work 
The SDEC-3000 and SDEC-4000 
DO NOT REQUIRE that you 
save at any time. When you are online and operating the unit 
your settings are being stored in protected memory at all times 
and no save process is required or possible. Saving your work 
is completely a safety copy in case anything happens to either 
the SDEC or your computer. 
 
Once you have completed the calibration and the final 
subjective listening tests you can save your work. Two copies 
should be saved. The first is a copy on your computer that you 
can distribute to other installers or keep as a backup on your 
own computer incase anything happens to the SDEC. The 
second is a copy that will be kept on the SDEC itself that can 
be retrieved in case your copy becomes corrupted or lost. 
11.1 Save a copy using SAVE AS 
Once finished but still connected to the Ethernet Network go 
OFFLINE by clicking on the green check box labeled ONLINE. 
This will disconnect your software from actively controlling the 
unit. It is now possible to use Save As from the File menu and 
save a copy as any other Windows file can be saved. 
11.2 Save to Network Device 
Once finished but still connected to the Ethernet Network go 
OFFLINE by clicking on the green check box labeled ONLINE. 
This will disconnect your software from actively controlling the 
unit
. You must first save the file to your computer using 
SAVE AS and name it a unique name for this install. It is 
now possible to use Save To Device Network from the File 
menu and save a copy to the SDEC itself. This can be 
retrieved by using the Open from Device Network menu 
explained below.  
 
12 Recalling Saved Settings 
Recalling your settings assumes that you are using London 
Architect to open and control the SDEC. If you are using the 
web interface (version 1.01 of the design file or higher) you will 
not need to recall settings as the settings will automatically be 
recalled. Settings can be retrieved from a number of different 
ways. Please read below for the different options. The London 
Architect software will automatically check to match the 
settings in your software against the hardware and give you 
options when opening the file and going online. 
 
Note: If you do not have a copy of the saved file and 
cannot recall from the device network DO NOT update the 
design file. You MUST have the same design file that was 
used to calibrate the system, even if it is not the saved file. 
Please contact JBL Synthesis Tech Support for more 
information if you have this problem. 
12.1 Recalling from a Saved File 
If you have the saved file from the London Architect software 
you can simply open it with London Architect and you will now 
have the same settings as before. 
12.2 Recalling without a Saved File 
You must have a copy of the same design file that you 
originally used to do the calibration, even if you have not a 
saved copy. This is the same file that is saved in the SDEC but 
all the settings are flat with no EQ or calibration settings saved. 
This is the file you would have received from JBL Synthesis or 
opened from the device network originally. Using this “blank” 
file to connect to the SDEC. When you first go online you will 
be prompted to select from synchronizing the settings from 
your computer software or synchronizing from the hardware 
device. Choosing hardware device will recall all the settings 
from the hardware and show them in the software on your 
computer. 
12.3 Recalling from Network Device 
If a copy of the file has been saved to the SDEC itself it can be 
recalled from the device. After opening the London Architect 
software go to File
 Open from Network Device. You will be 
prompted for a password and user login if necessary and 
shown a list of available files to open.  
Parametric Filter Values 
Octave Width 
 
Fractions 
Decimals 
  1/12 
0.08 
  1/10 
0.10 
  1/9  
0.11 
  1/8  
0.13 
  1/7  
0.14 
  1/6  
0.17 
  1/5  
0.20 
  1/4  
0.25 
  1/3  
0.33 
  2/5  
0.40 
  3/7  
0.43 
  4/9  
0.44 
  1/2  
0.50 
  4/7  
0.57 
  2/3  
0.67 
  3/4  
0.75 
  7/8  
0.88 
1       
1.00