6.2. Setting Output Parameters 
Signal processing for each output channel is programmed independently via the separate Output 
menu associated with each channel.  The signal processing parameters are described below in menu 
order. 
 
To access the Output menu pages for a particular channel 
  Press its yellow 
MENU ACCESS button (1 – 8) to switch to its menu.  
  Press the button repeatedly to step through the pages in turn.  Note that, after the last page, 
the next button press will cycle the menu back to the first page.  
 
To skip across to the same parameter on another output, press its MENU ACCESS button. 
6.2.2 
Naming the Output Channel (Page 1) 
Each output channel can be allocated a name up to 
8 characters long, which will be shown in the first 
page of the menu for easy reference.  The default 
names are Output 1, Output 2, etc.  Names are 
retained after power down and are included in 
stored settings. 
 
To enter a name 
Turn the left-hand knob clockwise to access 
the Output Name menu page. 
Use the centre knob to move the cursor right or left, and the right-hand knob to select the 
letter, number or symbol.   
On completion, turn the left-hand knob anti-clockwise to go back to the main page. The new 
name is now shown to the left of the menu page.  
6.2.3 
Routing (Page 2) 
Each output of the DN9848 can be acquired from a single input, a pair of outputs or all outputs.  For 
paired outputs, the source inputs are attenuated by 6dB prior to summing and the ratio of the two 
signals used is adjustable.  When all outputs are 
combined, the source inputs are attenuated by 12dB 
prior to summing in equal proportion.  (See Section 6.1 
for Technical Overview). 
For easy access and reference purposes, the routing is 
selected in the first menu page as shown opposite. 
 
To set the routing for the output 
Turn the centre knob to select the required 
source from the following sequence of choices:  
A, B, C, D, A+B, C+D, All. 
If you select A+B or C+D, use the right-hand knob to set the ratio for the signals, i.e. A:B or 
C:D, respectively. 
Important! Delays for the summed channels must be set to the same value. 
The ratio of paired 
outputs is adjustable.  
User defined  