Pelco ICIICISS45 User Manual

Page of 4
C1054M (6/99)
ICIICISS45
Inter-Check
®
 Interface Cable
300 W. Pontiac Way,
Clovis, CA 93612-5699
USA
In North America & Canada:
Tel (800) 289-9100
FAX (800) 289-9150
DataFAX (800) 289-9108
International Customers:
Tel (1-559) 292-1981
FAX (1-559) 348-1120
DataFAX (1-559) 292-0435
Pelco Online
http://www.pelco.com
®
DESCRIPTION
The ICIICISS45 Inter-Check
®
 interface cable is designed to connect an ICL/Fujitsu ISS45 sys-
tem terminal to the Inter-Check
®
 ICI1000S Series video text inserter. The interface cable con-
sists of a printed circuit board, two DB25 connectors (male and female), and a 6-foot (1.8 m)
data cable with an RJ-14 connector.
INSTALLATION
The following items are supplied:
1
ICIICISS45 Inter-Check
®
 interface cable
1
CN17-0111-0002 adapter, 25-pin (F) to 9-pin (M)
1
CN17-0211-0001 adapter, 25-pin (M) to 9-pin (F)
Refer to Figure 1.
1.
Turn off power to the ISS45 terminal.
2.
If the ISS45 terminal is equipped with a customer pole display, unplug the cable connec-
tor from port 3.
3.
Plug the CN17-0111-0002 adapter (supplied) into the 9-pin port 3 of the ISS45 terminal.
4.
Set the SW1 switch on the ICIICISS45 interface cable in the position toward the gray data
cable.
5.
Plug the ICIICISS45 interface cable connector into the CN17-0111-0002 adapter socket.
If the ISS45 terminal is equipped with a customer pole display, go to step 6; if not, go to
step 8.
6.
Plug the CN17-0211-0001 adapter (supplied) into the ICIICISS45 interface cable socket
(if the ISS45 terminal is equipped with a customer pole display).
7.
Plug the customer pole display (if equipped) cable connector into the CN17-0211-0001
adapter.
8.
Plug the ICIICISS45 data cable RJ-14 connector into the DATA IN receptacle of the
ICI1000S video text inserter or into the ICI1000WK wiring kit receptacle.
9.
Enable the customer pole display port if not previously being used.
10. Make certain all connections are tight. This completes the ICIICISS45 interface cable in-
stallation. The ISS45 terminal must now be programmed by a qualified technician or
dealer for the following parameters: 9600 baud, 8 bits, and parity off.
NOTE:
Both RJ-14 receptacles
in the ICI1000WK wiring kit (sup-
plied with the ICI1000S) must be
connected at the black and yel-
low terminals with 18 AWG two-
conductor shielded cable (refer to
the ICI1000S manual).
Figure 1.  ICIICISS45 Inter-Check
®
 Interface Cable
CUSTOMER POLE
DISPLAY CABLE
TERMINAL
PORT 3
ADAPTER
ICIICISS45
ADAPTER
DATA CABLE
TO ICI1000S
SWITCH
SW1