Hardware Installation Guide for the Polycom SoundStructure C16, C12, C8, And SR12
2 - 6
Rack-Mounting The Polycom SoundStructure Device
The Polycom SoundStructure can be mounted in an equipment rack, or placed 
on a tabletop or other flat surface, or mounted under the table with the 
optional undertable mounting kit.
To rack-mount the SoundStructure unit:
1.
Remove the four front screws on the enclosure. 
2.
Align the rack ears, and install the rack ears using the screws that were 
removed from the enclosure.
3.
Mount the equipment in the rack and secure with the four supplied rack 
mount screws (screw size is 10-32x1/2").
To place on a tabletop or other flat surface:
>>
If the equipment will not be mounted in an equipment rack, it is 
recommended that you install the four adhesive rubber feet on the bottom 
of the device (as shown below) before placing the equipment on furniture.
Warning
Each SoundStructure device requires one rack space and does not require 
additional empty rack spaces above or below the device. 
When multiple devices are racked together, before final tightening of the rack mount 
screws on each device after the first one, ensure there is enough clearance so that 
the front-panel door will open freely.