Hardware Installation Guide for the Polycom SoundStructure C16, C12, C8, And SR12
2 - 14
At rates at or above 38,400 bps, it is recommended that flow control be enabled 
on the control system.  The SoundStructure device will detect the use of flow 
control automatically - no user adjustment is required to turn flow control on 
or off on the SoundStructure devices.
The maximum length of an RS-232 cable is determined by the overall 
capacitance of the cable.  For practical purposes, the length of the RS-232 cable 
should not exceed fifty feet.
Making Audio Connections
SoundStructure devices provide balanced audio input and output connections 
that are terminated with 3.5 mm terminal blocks. For each balanced analog 
input or output on the SoundStructure rear-panel, the first pin should be 
connected to the positive signal, the second pin is connected to the negative 
signal, and the third pin is chassis ground as shown in the balanced audio 
SoundStructure
Control System
Pin
Signal
Pin
Signal
1
-
1
-
2
TX
2
RX
3
RX
3
TX
4
-
4
-
5
Ground
5
Ground
6
-
6
-
7
CTS
7
RTS
8
RTS
8
CTS
9
-
9
-