Setup Menu 
47
Setup Name 
Setup Description 
Setup Parameters 
42 
Time Code: Frame Rate 
Sets the time code frame rate. All com-
mon time code frame rates are available. 
• 23.976 – used with high definition video 
cameras 
• 24 – to sync audio to film where no transfer to 
NTSC video is expected 
• 25 – to sync sound to PAL video 
• 29.97 – to sync sound to NTSC video shot in 
non-drop frame mode 
• 29.97DF - to sync sound to NTSC video shot 
in drop frame mode 
• 30 – to sync sound to film where transfer to 
NTSC video is expected 
• 30DF – to sync sound to film for transfer to 
NTSC video in drop-frame mode 
43 
Time Code: Mode 
Sets the mode for the time code genera-
tor 
• Off – time code not active, recorded or output 
• Free Run – time code is initialized from 
the jam menu and then runs continuously 
regardless of record mode 
• Continuous Jam – time code is initialized 
from an external source and updates itself to 
the external source when reconnected 
• Record Run – time code is set from the jam 
value item in the jam menu. Time code 
generation starts and stops with the record 
key creating continuous time code from file 
to file. 
• 24 Hr Run – time code is initialized from the 
system clock on startup and enters free run 
mode. Time code is updated if the time of 
day clock is adjusted. 
44 
Time Code: User Bits 
Sets the time code user bits generated 
by the 744T. 
• Not Used – user bits are not set or output 
• yy:mm:dd.tt – user bits are set to a North 
American-style date with take counter 
• yy:dd:mm.tt – user bits are set to a Euro-
pean-style date with take counter 
• uu:uu:tt:tt – user bits are set to 4 user defin-
able digits with 4 take digits 
• tt:tt:tt.tt – user bits are set to the take counter 
for all 8 digits 
45 
Time Code: Jam Menu 
Allows the user to jam or edit the internal 
time code generator and user bits. (Also 
accessible by pressing HDD and Menu 
keys simultaneously). 
• Jam RX TC – jams the internal generator to 
received external code 
• Jam Zeros – resets the internal generator to 
zero 
• Jam Value – sets the internal generator to the 
value set in edit value 
• Edit Value – allows to user to enter a free-
form number to initialize the time code 
• Edit U-Bit – allows the user to edit allowed 
user bit numbers 
46 
Output 1 L,R: Source 
Selects the signal source for the Master 
Output Bus (TA3 outputs, tape outputs, 
and digital 1 outputs.  
• inputs 1 / 2 
• inputs 3 / 4 
• tracks A / B 
• tracks C / D 
• monitor A / B (post-record monitor) 
• monitor C / D (post-record monitor)  
47 
Output 1 L,R: Attenuation 
Selects the attenuation level of signal 
sent to the Master Output Bus. 
selectable from 0 to 
−40 dBFS