ICOM IC-V85-T User Manual

Page of 80
25
5
REPEATER OPERATION
The USA version automatically activates the repeater settings
(duplex ON/OFF, duplex direction, tone encoder ON/OFF)
when the operating frequency falls within or outside of the
general repeater output frequency range. The offset and re-
peater tone frequencies are not changed by the auto repeater
function. Reset these frequencies, if necessary.
q While pushing and holding 
[
Y
Y
]
and 
[
Z
Z
]
, turn the power ON
to enter 
INITIAL SET MODE
.
w Push 
[
Y
Y
]
or 
[
Z
Z
]
several times until “RPt” appears.
e Rotate 
[VOL]
to select the desired condition.
• “OF”— the auto repeater function is turned OFF;
• “R1”— the auto repeater function activates duplex only;
• “R2”— the auto repeater function activates duplex and tone.
r Push 
[
ENT
]
(or 
[CLR]
) to exit 
INITIAL SET MODE
.
• Frequency range and offset direction
Frequency range
Duplex direction
145.200–145.495 MHz
“–” appears
146.610–146.995 MHz
147.000–147.395 MHz
“+” appears
Auto repeater function 
(USA version only)
USING