Atlona AT-HDWP-IR-UK User Manual

Page of 14
7
atlona.com
Toll free: 1-877-536-3976
Local: 1-408-962-0515
Captive Screw
Connecting
IR captive screw connector is an added feature on the HDWP-IR-UK. The Captive screw connector allows you 
to cut cables down to a suitable length, reducing cable clutter and providing a more reliable connection.
The captive screw connectors have a contact bar that is moved to compress the wire to the top contact 
plate. Use the screws at the top of the connector to compress the wire against the contact plate.
When connecting the cables to the female captive screw connector it is important that the wires be 
terminated correctly. The female captive screw connector (see picture A) has a contact plate at the top and 
must have the wires touching it for signal to pass. When wired correctly (see picture B) the signal will pass, 
incorrectly (see picture C) no signal will pass.
For your convenience the cables do not come pre-terminated. Each item, whether it’s an IR receiver (picture 
1) or IR emitter (picture 2), will have wires exposed. Each wire is encased in a different colored cover. Female 
captive screw connectors are included: IR (see picture 3).
IR pin outs have been included for the included IR emitter and IR receiver (see picture 6 & 7). The wires are 
colored for each pin (see picture 8 and 9). *IR used with HDTX-IR and HDRX-IR only*
White: -   Red:+
Red: PWR White: IR Black
2
1
IR
Clockwise
Counter
Clockwise
Turn the screws clockwise to 
raise the contact bar to the upper 
contact plate and hold the wires 
in place.
Turn the screws counter clockwise 
to lower the contact bar to release 
the wires.
3
6
7
8
9
A
B
C
-  
 
 
+
Emitter
PWR IR
Receiver