Broan SPA1600D User Manual

Page of 8
13
14
T
ROUBLE SHOOTING THE SYSTEM
We have put together this trouble-shooting guide if you experience problems after 
installing the amplifier. Please keep in mind that the majority of problems incurred are 
caused by improper installation and not the equipment itself. In addition, there are many 
components in the system that could cause various signal problems such as inducted 
electrical noise and engine noise.
Before you can properly address the problem, you must first find the component that is 
causing the problem. This will take patience and a process of elimination.
 
LOOK FOR…..   
 
 
SOLUTION
No Output
 
Blown fuse 
 
 
 
Replace
 
Bad RCA Cable(s) 
 
 
Replace
 
+12V at power terminal 
 
 
Check connection
 
+12V at remote terminal   
 
Check connection
 
Grounding point clean and tight 
 
Check for ground w/meter
 
Head Unit’s fader not in center position 
Set to center position
 
Master & Slave settings   
 
Confirm correct setting
Low Output
 
Check level adjustments   
 
 
 
 
Re-adjust
 
Bad RCA cable(s)  
 
 
Replace
 
Improper level matching   
 
Re-adjust
 
Master & Slave settings   
 
Confirm correct setting
Engine Noise
 
Grounding points are clean and tight 
Check for ground w/meter
 
Ground all components at same point 
Ground at same point
 
Try different grounding point 
 
Change for better ground
 
Bad RCA cable(s)  
 
 
Replace
 
Use High Quality shielded RCA cables 
Rejects inducted noise
 
Low Vehicle charging system and/or battery  Fix and/or replace
Red Protection L.E.D. illuminated
 
Speaker short 
 
 
 
Check speakers connection
 
 
 
 
 
 
   for short circuit
 
Speaker grounding out 
 
 
Make sure speaker wires
 
 
 
 
 
 
Do not touch chassis ground
 
Impedance too low 
 
 
Check speaker impedance
 
Overheating 
 
 
 
Check mounting location
 
 
 
 
 
 
   for Adequate air circulation
 
 
 
 
 
 
   speaker impedance too low
S
PECIFICATIONS
Input Voltage @ 11 - 14.4 VDC:
 
@ 4 ohm
 
@ 4 ohms Bridged
 
@ 2 ohm
Frequency Resp.
S/N Ratio (A-weight)
Low Input Level
Crossover Type
Crossover Freq. (Lowpass)
Crossover Slope
Bass EQ.
Fuse Rating
Remote Bass
SPA90.2
2 x 90W
1 x 350W
2 x 175W
10Hz-20Khz
>90dB
200mV. - 5.8 V
Hi/Low Pass
55Hz - 400Hz
12db per oct
18dB @ 45Hz
2 x 20 amp
no
SPA1000D
1 x 250W 
1 x 500W
1 x 1000W
20Hz - 250Hz
>90dB
246mV - 5.9V
Low Pass
40Hz - 150Hz
18dB/oct
18dB @ 45Hz
20Hz - 50Hz
Yes
2 x 20 amp
included
Input Voltage @ 11 - 14.4 VDC:
 
 @ 4 ohm
 
 @ 2 ohm
 
 @ 1 ohm
Frequency Resp.
S/N Ratio (A-weight)
Low Input Level
Crossover Type
Crossover Freq. (Lowpass)
Crossover Slope
Bass EQ.
Subsonic Filter
Remote Control Included
Fuse Rating
Remote Bass
Input Voltage @ 11 - 14.4 VDC:
 
@ 4 ohm
  
@ 2 ohm
 
 @ 1 ohm
Frequency Resp.
S/N Ratio (A-weight)
Low Input Level
Crossover Type
Crossover Freq. (Lowpass)
Crossover Slope
Bass EQ.
Subsonic Filter
Remote Control Included
Fuse Rating
Remote Bass
SPA1300D
1 x 325W
1 x 650W
1 x 1300W
20Hz - 250Hz
>90dB
246mV - 5.9V
Low Pass
40Hz - 150Hz
18dB/oct
18dB @ 45Hz
20Hz - 50Hz
Yes
2 x 25 amp
included
SPA1600D
1 x 400W
1 x 800W
1 1600W
20Hz - 250Hz
>90dB
246mV - 5.9V
Low Pass
40Hz - 150Hz
18db/oct
18dB @ 45Hz
20Hz - 50Hz
Yes
2 x 30 amp
included
SPA1900D
1 x 475W
1 x 950W
1 x 1900W
20Hz - 250Hz
>90dB
246mV - 5.9V
Low Pass
40Hz - 150Hz
18dB/oct
18dB @ 45Hz
20Hz - 50Hz
Yes
3 x 30 amp
included
SPA90.4
4 x 90W
2 x 350W
4 x 175W
10Hz-20Khz
>90dB
200mV. - 5.8 V
Hi/Low Pass
55Hz - 400Hz
12db per oct
18dB @ 45Hz
2 x 25 amp
optional
Due to continuous improvement of the product the Specifications are subject to change without notice.