SA-365-10   Installation Instructions 
05/24/10 
CP5036A 
TABLE OF CONTENTS 
GENERAL DESCRIPTION .................................................................................................... 2 
SPECIFICATIONS................................................................................................................. 2 
INSTALLATION ..................................................................................................................... 3 
SAFETY PRECAUTIONS................................................................................................. 3 
UNPACKING .................................................................................................................... 3 
OPTION SWITCHES ........................................................................................................ 4 
MOUNTING ...................................................................................................................... 5 
ELECTRICAL CONNECTIONS ........................................................................................ 5 
OPERATION ......................................................................................................................... 6 
POWER ON/OFF ............................................................................................................. 6 
YELP - STANDBY - WAIL  SELECTOR SWITCH............................................................. 6 
MANUAL / PHASER - HORN SWITCH ............................................................................ 6 
AUXILIARY INPUT FUNCTIONS...................................................................................... 6 
Horn Ring Cycler 2  (HRC2) ....................................................................................... 6 
SERVICE............................................................................................................................... 7 
PROBLEMS...................................................................................................................... 7 
PARTS and ACCESSORIES ............................................................................................ 7 
RETURNS......................................................................................................................... 8 
WARRANTY ..................................................................................................................... 8 
GENERAL DESCRIPTION 
The SA-365 Siren Amplifier is designed for single 100W speaker use.  The primary operating 
modes are Yelp, Wail and Standby, selected by a 3-position rocker switch.  Horn Override, push-
on/push-off Phaser operation in the Yelp and Wail modes, and Manual siren control in the 
Standby mode are controlled by a momentary 3-position rocker switch.  The unit features instant-
on allowing the unit to produce a tone instantly when a switch is activated.  A DIP switch provides 
options such as Two-Tone, disable tones, HRC2 operation, Auxiliary function, etc.  The unit util-
izes short circuit, high voltage, and reverse polarity protection systems for maximum service life.  
An output light indicates siren signal output for diagnostics and troubleshooting. 
SPECIFICATIONS 
NOTICE 
Due to continuous product improvements, we must reserve the right to change any specifications and information, 
contained in this manual at any time without notice. 
Carson Manufacturing Co., Inc. makes no warranty of any kind with regard to this manual, including, but not 
limited to, the implied warranties of merchantability and fitness for a particular purpose. 
Carson Manufacturing Co., Inc. shall not be liable for errors contained herein or for incidental or consequential 
damages in connection with the furnishing, performance, or use of this manual. 
 
See www.carsonsirens.com for latest information. 
Speaker Load 
Single 100W 11ohm 
Input Current 
8 AMPS (@14 VDC - single 100W speaker) 
Standby Current 
0 mA 
Output Power 
105 WATTS RMS MAX. (15 VDC - single 100W speaker) 
Siren Frequency 
700Hz - 1500Hz (Two-Tone and Horn = 435 & 585Hz) 
Tones / Cycle Rates 
 Horn 
Wail 
Yelp 
Phaser 
Two-Tone 
Cycle Rates 
109 CPS 
13 CPM 
190 CPM 
15 CPS 
60 CPM 
High Voltage Protection 
16 - 18 VDC will cause siren output to cease, resume at normal voltage 
Short Circuit Current 
50 AMPS (supply circuit must be capable of supplying this for 1 second) 
Operating Temp. 
-15° F to +140°F 
Controls 
3-position rocker selector switch (Yelp, Wail and Standby). 
3-position momentary rocker switch (Horn and Manual/Phaser toggle). 
Positive or Negative Auxiliary input. 
8-position DIP switch option selector. 
Connections (6-Pin Conn) 
Positive, Negative, (2) Speaker, and Auxiliary +/-. 
Size 
4-1/2" Wide, 1-13/16" High, 4-13/16" Deep 
Weight 
3 LBS. 
Input Voltage 
10 - 16 VDC (negative ground)