Speco Technologies IP-INTT5 User Manual

Page of 126
 
 
126 
IP Camera User’s Manual 
Speco Technologies 
 
Check with ‘C-1-2 Network Cable (LAN cable) and cable connection check’. 
 
PING Test 
 
In case Camera uses Static/Public IP: input “Ping IP address” to
 
command window 
of PC and check response. 
 
In  case  camera  uses  dynamic/public  IP:  In  this  case,  user  cannot  find  camera  IP 
address. So, reset hardware and connect PC with THE CAMERA through cross cable 
and ping test by “192.168.1.7”. 
 
In  case  camera  uses  private  IP  through  IP  sharing  device:
 
Ping-test  private  IP 
address set for THE CAMERA in PC that is connected in the local network through IP 
sharing device. 
 
If “ping test” get response, network setting for camera is done correctly. 
 
If ping test is okay but there is no connection
,
 check with ‘C-2-2 check port setting’.. 
 
C-2-2. Check Port Setting 
 
If  user  can’t  connect  with  camera  even  though  ‘Ping  test’  is  okay,  please  check  port 
setting by the following steps. 
 
THE CAMERA uses 3 ports as follow. 
 
Web Connection Port                         : Port 80 TCP 
 
 
Authentication and Control Port  : Port 9000 TCP 
 
Video Streaming Port     
: Port 9001 TCP 
 
Motion Detection Control Port        : Port 9005 TCP 
 
If  it  is  not  available  even  to  connect  to  web,  check  web  connect  port  because  web 
connect port may be set with other number than ‘80’.   
 
In case there is problem in video monitoring even though there is no problem in Web   
connection, check if  ‘Authentication and Control Port’ and  ‘Video Streaming Port’ of THE 
CAMERA is set on IP sharing device (in case of using IP sharing device).   
 
For setting of IP sharing device Port, refer to ‘IP sharing device Setting’. 
C-3  In case web page can’t be connected under ultrahigh speed internet line 
 
Some  ultrahigh  ISP  company  may  block  not  to  use  Web  port  number  80.  In  this  case, 
change to other number from web connection port setting.