EverFocus EIP220 User Manual

Page of 32
 
 
IP99 series 
 21
selected area, click “Remove region”. Please refer to diagram 3.4: 
 
Diagram 3.4 Alarm event 
 
1)Motion detection event: No event, send JPEG file by e-mail or upload to FTP.   
Note: When sending JPEG by e-mail or upload to FTP, file will be sent to the 
assigned e-mail adress. 
 
2)Alarm I/O setting: Set Alarm Input/Output setting and status, as shown in diagram 
3.5: Select Alarm input level high, low or no alarm for each AI alarm inputs. Different 
alarm actions: send JPEG file by e-mail, load to FTP or no action can be selected. In 
Alarm Output table, the current status of AO1 and AO2 are shown. The output of AO1 
and AO2 can be changed remotely by clicking High or Low button and do Save. 
AO1/AO2 will output 3.3V or 0V TTL level to the terminal. 
 
 
 
 
 
Diagram 3.5 Alarm I/O setting