First Alert K5309-5V2 User Manual

Page of 64
 
– 28 – 
3DJLQJ)HDWXUH
 
$ERXW$XWRPDWLF3DJLQJ
Your system may be set up to automatically send alert messages to several pagers (up 
to four for FA168CPS, up to two for FA148CP) as certain conditions occur in your 
system. 
•  The following events can be programmed by your installer to be sent to the pagers: 
arming and disarming
, alarms, and trouble conditions. (
  reports when 
arming/disarming from a keypad using a security code; auto-arming/disarming, 
arming with assigned button, and keyswitch arming do not send pager messages.) 
•  You can also program the system to send an automatic pager message to alert you 
in the event that someone has not arrived home (disarmed the system) within a 
defined period of time (see the Scheduling section for details on programming a 
“latch key report”). 
•  Your installer programs the pager phone numbers and reporting events. 
•  The pager message consists of a 7-digit system status code that indicates the type of 
condition that has occurred. 
•  An optional, predefined 16-digit character string can precede the 7-digit system 
status code; these characters can consist of a PIN no., subscriber account no., or any 
additional data that you may wish to have sent to the pager. 
•  The pager display format is as follows: 
 
Optional 16 digits
 
3-digit Event Code 
 
È
È 
È
È 
AAAAAAAAAAAAAAAA – BBB – CCCC 
Å
Å 
1-digit Partition No. + 3-digit Zone No. or User No.
 
 
A = 
B = 
C = 
Optional 16-digits for 
Account numbers, 
PIN numbers, or any 
other data; 
programmed by the 
installer, if required. 
A 3-digit code that 
describes the event 
that has occurred 
in your system 
(see for event 
codes table below) 
A 1-digit Partition number plus a 3-digit Zone or User 
number, depending on the type of event that has 
occurred, where: 
• alarms and troubles display zone number 
• arming/disarming (opens/closes) display user number 
 
The 3-digit Event Codes (BBB) that can be displayed are: 
911 = 
811 = 
101 = 
102 = 
Alarms. 
The 4-digit number 
(CCCC) following this 
code is the partition no. 
and zone no. that 
caused the alarm. 
Troubles. 
The 4-digit number 
(CCCC) following this 
code is the partition no. 
and zone no. that 
caused the trouble. 
Open 
(system disarmed). 
The 4-digit number 
(CCCC) that follows 
this code is the 
partition no. and user 
no. 
that disarmed the 
system. 
Close 
(system armed). 
The 4-digit number 
(CCCC) that follows 
this code is the 
partition no. and user 
no. 
that armed the 
system. 
 
Ex. 1. 
³  = Reporting of an alarm (911) caused by a fault on zone 4 on Partition 1 (1004). 
Ex. 2. 
³ = Reporting of a closing–system arming (102)– by user 5 in Partition 2 (2005).