Faber M640 User Manual

Page of 127
68    Operational Reference 
Genie Monochrome Series-GigE Vision Camera 
Power-up Control via Sapera LT or GenICam Applications 
 
 
Sapera
 
Genie Sapera parameters for Power-up Configuration: 
Power-upConfig = {Factory Default = 0, Camera Configuration 1 = 1} 
SaveCameraConfigurationSelector = {Camera Configuration 1 = 1} 
SaveCameraConfiguration = Write to save selected camera configuration 
LoadCameraConfigurationSelector = {Factory Default = 0, Camera Configuration 1 = 1} 
LoadCameraConfiguration = Write to load selected camera configuration 
In CamExpert, these parameters are available in the “Camera Information” tab, under the “Power-
up Configuration” dialog box. 
See 
"
.  
 
 
 
GenICam features for Power-up Configuration: 
UserSetSelector = {Factory = 0, UserSet1 = 1} 
UserSetLoad = Loads the User Set specified by UserSetSelector to the camera and makes it 
active 
UserSetSave = Saves the User Set specified by UserSetSelector to the camera 
UserSetDefaultSelector = Selects the feature User Set to load at camera reset 
 
 
Sapera Supported Features List 
The Genie features and its currently set values can be read by a Sapera application. The Sapera tool CamExpert is 
an example of an application that reads and writes Genie parameters to control its operation.  
The following tables group the Genie features by their feature type—STRING, ENUM, INT32, and BOOL. 
Features may be read only (RO), read/write (RW), or write only (WO).  
Accessing Features with Sapera++ LT 
When working with Genie features, the SapAcqDevice class provides functions for accessing features from devices 
such as a GigE-Vision camera. The class also contains functions for sending commands and registering events to 
devices.  
•  SapAcqDevice::GetFeatureInfo returns information on a feature associated with a specified name or 
index.  
•  SapAcqDevice::SetFeatureValue writes a new value for a feature.  
•  All information about the feature is stored in a SapFeature class object.  
Refer to the Sapera++ LT Programmer's manual (OC-SAPM-SPPP0).