7.4 
Alarm 
 
External alarms and motion sensors can be set. Connecting a sensor or other 
device to the alarm input terminal notifies an alarm when the sensor detects a 
trouble.  For example, mounting a sensor on a door notifies an alarm each time the 
door is opened. By setting the motion sensor to activate, an alarm is notified by 
detecting a change in a screen. 
 
One Alarm input1 terminal is indicated on external cable. You need to define some 
parameters before u sing the alarm function. 
7.4.1 
External digital input 1 
 
z
 
Set an "Alarm Input" 
ON: Detects an external alarm. 
OFF: Does not perform alarm detection.  
Î
 
The following functions will be enabled if “ Alarm Input” is set to “ON” 
z
 
Set "Input type" for alarms 
Normally Opened (NO): A dry-contact detecting way, opened if nothing occurs 
but closed in case of an alarm. 
Normally Closed (NC): A dry-contact detecting way, closed if nothing occurs but 
open in case of an alarm. 
z
 
Set "TEXT Enable" for alarms 
A noticeable message of alarm can be displayed on screen if this item is set to 
“ON”. 
z
 
Enter "Text" for alarm message 
Max 24 characters can be entered. 
z
 
Set "Audio out" for alarm message 
Audio alarm message can be sent to external speaker if this item set to “ON”.