6.2.7. LVAL synchronous accumulation 
With LS=0, the accumulation will start synchronously with LVAL. The trigger pulse should be 
longer than 2 LVAL intervals, and the accumulation will then start at the first LVAL after the 
trigger leading edge. The exposure start delay will be up to 1 line. (Single channel 47.9 µsec. 
Dual 27.3 µsec).   
In EPS mode the exposure stops 0.5 L after the selected shutter time, (in number of LVAL).  
In PWC mode the exposure stops 0.5 L after the first LVAL after the trigger trailing edge. It 
results in up to 1 LVAL jitter. 
In LVAL synchronous accumulation mode a new trigger can start a new exposure during the 
previous frame read out, but the exposure may not be finished before the frame is read out. It 
makes it possible to have a trigger rate close to the frame rate. (1 FVAL + 3 LVAL). 
 
Important notes on using this mode. 
In LVAL synchronous PWC mode exposure jitter up to 1 LVAL can be the result, if the trigger 
trailing edge is not synchronized to LVAL. 
LVAL
Ext . Tr i g
Mi n. : 2L
0. 5L
SUB
SG
Exposur e
Per i od
Vi r t ual   SUB
Equi val ence
Pul se
Dat a- out   del ay
Si ngl e:   1. 5L
Dual :   1. 5L
FVAL
Speci f i ed  Number   of   LVALs
by  shut t er   set
Act ual   Exposur e  Per i od
DATA  OUT
OB
OB
Exposur e  del ay:
Max  1L
 Fig. 21. LVAL synchronous accumulation in EPS mode 
 
LVAL
Ext . Tr i g
0. 5L
SUB
SG
Exposur e
Per i od
Vi r t ual   SUB
Equi val ence
Pul se
Dat a- out   del ay
Si ngl e:   1. 5L
Dual :   1. 5L
FVAL
Act ual   Exposur e  Per i od
DATA  OUT
OB
OB
Del ay  of   exposur e  st ar t   :
Max  1L
Del ay  of   exposur e  end  :
Max  1L
 