7-2. Jumpers on board
7-2-2. Jumpers on PK8202 board
Jumpers JP5, JP6 and JP7 enable or disable the ext. trigger input, the WEN output and pixel
clock output, respectively.
7-2-1. Jumpers on PK8201 board
Jumpers JP1 and JP2 are used to select the gamma setting. See table below for options.
Please note that both jumpers must be in the “open” position to allow RS 232C setting of
gamma. If no setting is provided via RS 232C, the camera will default to gamma 1.0.
Do not set the jumpers both JP1/JP2 at short circuited, as it causes a serious damge to the camera.
Note : Gamma is set at “Setting by RS 232C interface” with 1.0.
Jumpers
Setting by jumpers
Setting
by
RS 232C
Forbidden
0.45
1.0
JP1
Short
Open
Open
Short
JP2
Open
Short
Open
Short
JP1
JP2
#5 of 6pin connector
#6 of 6pin connector
#9 of 12 pin connector
NC
Open
Trigger in
Short
NC
Open
WEN out
Short
Jumpers
JP5
JP6
JP7
NC
Open
Pixel clock out
Short
H Reset Trigger Mode and H Non Reset Trigger Mode are corresponding
to the following triggers: Edge Pre-select Mode, Pulse Width Control
Mode, and Frame Delay Readout Mode
(12P): Trigger Mode using only 12 pin connector
(6P): Trigger Mode where 6 pin connector is used for both Trigger and
WEN, and 12 pin connector is used for HD input.
JP7 and JP18 must not be SHORT at the same time.
Function Mode
Rear Board (PK8202)
JP5  JP6  JP7 JP18 JP19 JP20 JP21
Int. Sync
O  O  O/S O/S O/S  O  O/S
Ext. Sync
O  O  O/S O/S  S  O  S
H Rest Trigger (12P)
O  O  O/S O/S  S  O  S
H Non Reset Trigger (12P)  O  O  O/S O/S  S  O  S
H Rest Trigger (6P)
S  S  O/S O/S  O  O  O
H Non Reset Trigger (6P)  O  S  O/S O/S  O  S  S
O=Open S=Short
JP19
JP21
JP20 JP5
JP18
JP6
JP7
CAUTION