JAI CV-L105 User Manual

Page of 22
CV-L105
 
6.2.1. Internal Trigger. Scan mode. 
In this mode, the camera does not require an EXT TRIG signal to be issued to the camera. The 
line rate (scan rate) is generated inside the camera. The camera will operate continuously with 
its internal trigger.  
The exposure time is equal to the scanning time set by the SCAN parameter via RS-232C. 
The permitted range for the scan rate is 151 µs to 32.5 ms (corresponds to 6.6 kHz to 30 Hz). 
SHUTTER parameter has no function here. 
 
 
To use this mode: 
Set function: 
Trigger 
Internal 
 
 
 
 
Mode 
SCAN 
  
 
 
 
SHUTTER  value 
No function 
 
SCAN value 
151 µs through 32.5 ms 
 
 
 
 
Clock, Binning and other functions 
 
Input:    
 
  
 
 
 
 
 
 
Important notes on using this mode:
-
 
•  It is only recommended to use this mode when there is not change of speed in the object 
being scanned. If the speed of the object changes, the aspect ratio in the vertical 
(scanning) direction will change. 
•   
 
 
 
LEN
Data out
Exposure
Exposure time = SCAN value
LEN
Data out
Exposure
Exposure time = SCAN value
 
 
 
 
 
 
 
30 MHz  1t=33.3 ns 
15 MHz   1t=66.6 ns 
Value in ( ) is for Binning
 
 
 
 
 
Fig. 12. Timing for internal scan mode 
 
- 10 -