JAI CV-M91 User Manual

Page of 28
CV-M91
 
 
- 21 - 
   
 
7.3. RS-232C control 
The CV-M91 camera functions can be set up via the RS-232C port on the 6 pin HR connector. The 
JAI camera control tool for CV-M91 can be used for it.  
 
To use this mode:  
Set function: 
Control. SW1-8 on rear to ON. RS-232C. (Switch setting before power on).
 
 
 
 
 Other 
functions 
 
Important notes on using this mode. 
•   
 
 
Communication setting.  
Baud Rate 
9600 bps 
 Data Length 
8 bit 
Start Bit 
1 bit 
Stop Bit 
1 bit 
Parity None 
Xon/Xoff Control  None 
 
 
 
RS 232C cable 
TXD
RXD
GND
1 CD
4 DTR
6 DSR
2 RXD
3 TXD
5 GND
7 RTS
8 CTS
9 CI
9 pin
D-con
PC COM
PORT 
CAMERA
TXD
RXD
GND
1 CD
4 DTR
6 DSR
2 RXD
3 TXD
5 GND
7 RTS
8 CTS
9 CI
9 pin
D-con
PC COM
PORT 
CAMERA
  
7.4. CV-M91command list 
The following functions can be controlled via the camera control tool. 
 
Shutter speed 
 
1/60 to 1/10,000 sec. 
Mode 
 
Normal, random trigger 
Scanning 
 
2.1 interlaced, non-interlaced 
Accumulation 
 Frame, 
field 
Gamma 
 
Gamma 1.0, gamma 0,45  
AGC 
 
AGC off, AGC on, manual gain, AGC reference level 
CCD iris 
 
CCD iris on. CCD iris off, CCD iris reference level 
White balance 
 
One push, manual, red gain, blue gain, green gain 
White clip level 
 
Red white clip, blue white clip, green white clip 
Offset level 
 
Red offset, blue offset, green offset 
Load user settings 
 
Load factory, user 1, user 2 
Save user settings 
 
Save user 1, save user 2. (Last saved user settings become default at next power-up.)