Lucent Technologies 8.2 User Manual

Page of 1707
DEFINITY ECS Release 8.2
Administrator’s Guide  
555-233-506  
Issue 1
April 2000
Screen reference 
1021
Trunk Group 
17
Field descriptions for page 4
This screen appears when the Direction field on Page 1 is 
outgoing
 or 
two-way
 
and the ATMS field is 
y
 on the Feature-Related System Parameters screen.
The figure below shows a common configuration for page 4 of the Trunk Group 
screen when the Group Type field is 
co
. This screen is only an example, and the 
fields shown below may change or disappear according to specific field settings.
Screen 213.
CO Trunk Group ATMS Thresholds 
!
CAUTION:
Customers: Do not change fields on this page without assistance from 
Lucent Technologies or your network service provider.
50
The TN465B (or later) and TN2184 can only detect 12k and 
16kHz PPM. Therefore, if 
50
 is administered, the circuit pack 
will be set to detect 16kHz.
50/12k
 
The TN465B (or later) and TN2184 can only detect 12k and 
16kHz PPM. Therefore, if 
50/12k
 is administered, the circuit 
pack will be set to detect 12kHz.
50/16k
The TN465B (or later) and TN2184 can only detect 12k and 
16kHz PPM. Therefore, if 
50/16k
 is administered, the circuit 
pack will be set to detect 16kHz.
Valid entries
Usage
add trunk-group next
Page 4 of x
                          ATMS THRESHOLDS
TTL Type: _________
Far End Test No: __________________
  TTL Vendor: ______________            TTL Contact: ______________________
Trunk Vendor: ____________            Trunk Contact: ___________________
Trunk Length: _____
                         MARGINAL         UNACCEPTABLE
                         Min   Max          Min   Max
           1004 Hz Loss: __
__
__
__
                         -Dev  +Dev         -Dev   +Dev
            404 Hz Loss:
_
_
_
_
           2804 Hz Loss: 
_
_
_
_
Maximum C Message Noise:
__
__
Maximum C Notched Noise: 
__
__
         Minimum SRL-HI:
__
__
         Minimum SRL-LO:
__
__
            Minimum ERL:
__
__
      Allow ATMS Busyout, Error Logging and Alarming? _
  Maximum Percentage of Trunks Which Can Be Removed from Service by ATMS: __