1471
Remote Access 
20
Interactions
Authorization Codes
When a Remote Access caller dials the assigned Remote Access extension 
and connects to the system, the system may request the caller to dial an 
authorization code in addition to a barrier code. Dial Tone between the 
barrier code and authorization code is optional. Calling privileges 
associated with the COR assigned to the authorization code supersede 
those assigned to the barrier code.
Class of Restriction
COR restrictions do not block access to the Remote Access feature.
Night Service
The Remote Access extension can be specified as the Night Service 
extension on an incoming, non-DID, trunk group.
Related topics
Refer to 
‘‘Remote Access’’ on page 857
 for information about and field 
descriptions on the Remote Access screen.
Refer to 
‘‘Setting up remote access’’ on page 297
 for step-by-step instructions for 
configuring remote access.
Refer to 
‘‘Authorization Code — COR Mapping’’ on page 497
 for information 
about and field descriptions on the Authorization Code screen.
Refer to 
‘‘Trunk Group’’ on page 967
 for information about and field descriptions 
on the Trunk Group screen.
Reset Shift Call
Reset Shift Call allows users to redial a local or private network call by pressing a 
single digit. The switch plays reset shift dial tone on busy calls if:
A station or attendant originates a call
The dialed endpoint is in the dial plan and is one of the following types:
Extension (local or uniform dial plan (UDP))
Prefixed extension (local or UDP)
AAR