Lucent Technologies 8.2 User Manual

Page of 1707
DEFINITY ECS Release 8.2
Administrator’s Guide  
555-233-506  
Issue 1
April 2000
Managing data calls 
398
Default Dialing 
15
Considerations
A BRI phone cannot call a data terminal, and a data terminal cannot call a 
BRI phone.
Interactions 
Abbreviated Dialing
Only 22 of the 24 (maximum) digits in an abbreviated-dialing number are 
available for keyboard dialing. The remaining two digits must contain the 
wait indicator for tone detection.
Call Coverage
A hunt group made up of data endpoints cannot be assigned a coverage 
path.
Call Detail Recording
CDR records the use of modem pools on trunk calls.
Call Forwarding All Calls
Calls received by a data module can be forwarded. Activate Call 
Forwarding All Calls with data-terminal (keyboard) dialing. If the 
forwarded-to endpoint is an analog endpoint and the caller is a digital 
endpoint, modem pooling is activated automatically.
Pooled Modems with Hunt Groups
UCD can provide a group of data modules or analog modems for 
answering calls to connected facilities (for example, computer ports).
World-Class Tone Detection
Multiple-line data-terminal dialing is supported if the administered level of 
tone detection is precise. You can administer tone-detection options. The 
message that Data Call Setup sends to users varies according to the option.
If the option is not set to precise, and a data call is set up over an analog 
trunk, messages describing the status of the called endpoint (for example, 
RINGING, BUSY, TRY AGAIN) change according to which 
tone-detection option is selected.
Default Dialing
Default Dialing provides data-terminal users who dial a specific number the 
majority of the time a very simple method of dialing that number. Normal data 
terminal dialing and alphanumeric dialing are unaffected.