Managing data calls 
401
Data Privacy 
15
3. On the Data Module screen, administer the Abbreviated Dialing List1 field.
The system automatically places Data Hotline calls to preassigned extensions or 
off-premises numbers. Calling terminals are connected to the system by a data 
module. Users should store the destination number in the abbreviated dialing list 
for future reference.
Interactions
Call Forwarding — All Calls
A Data Hotline caller cannot activate both Call Forwarding and Data 
Hotline. Dialing the Call Forwarding feature access code (FAC) causes 
activation of the Data Hotline instead.
Data Privacy
Data Privacy protects analog data calls from being disturbed by any of the 
system’s overriding or ringing features.
Administering Data Privacy
1. Choose either of the following:
On the Feature Access Code screen, administer the Data Privacy 
Access Code field. Refer to 
‘‘Feature Access Code’’ on page 619
 for 
more information.
On the Class of Service screen, administer the Data Privacy field. 
Refer to 
‘‘Class of Service’’ on page 532
 for more information.
2. On the Station screen, administer the Class of Service field. Refer to 
‘‘Station’’ on page 882
 for more information.
To activate this feature, the user dials the activation code at the beginning of the 
call.
Considerations
Data Privacy applies to both voice and data calls. You can activate Data 
Privacy on Remote Access calls, but not on other incoming trunk calls. 
Data Privacy is canceled if a user transfers a call, is added to a conference 
call, is bridged onto a call, or disconnects from a call. You can activate Data 
Privacy on calls originated from attendant consoles.