Screen reference 
929
System Parameters Customer-Options 
17
G3 Version
Identifies the version of DEFINITY ECS being used. 
Maximum Ports
Number of ports active, per contract.
Location
Indicates the location of this switch. 1 indicates Canada or the United States. 2 
indicates any other location, and allows the use of International Consolidation 
circuit packs and telephones.
Maximum XMOBILE Stations
Specifies the maximum number of allowable XMOBILE stations. In general, each 
XMOBILE station is assigned to a wireless handset.
Maximum H.323 Trunks
Appears when the H.323 Trunks field is 
y
. Specifies the maximum number of 
H.323 trunks that may be administered.
Maximum H.323 Stations
Appears when the IP Stations field is 
y
. Specifies the maximum number of H.323 
stations that may be administered.
Valid entries
Usage
-
 36065 
(G3r)
-
 3500 
(G3vs/si/csi)
Shows the maximum number of XMOBILE stations. Each 
XMOBILE station counts as a station and a port in terms of 
system configuration.
Valid entries
Usage
-
 1000 
(G3r)
-
 300 
(G3si/csi)
Shows the maximum number of H.323 trunks. The combined 
total of H.323 stations, IP SoftPhones, and H.323 trunks cannot 
exceed 1000 for G3r or 300 for G3si/csi.
Valid entries
Usage
-
 1000 
(G3r)
-
 300 
(G3si/csi)
Shows the maximum number of H.323 stations. The combined 
total of H.323 stations, IP SoftPhones, and H.323 trunks cannot 
exceed 1000 for G3r or 300 for G3si/csi.