Saturation
 
The saturation register at offset 814h allows the intensity of the colors to be changed in the range of 0 ~ 255.   
For Saturation control inquiry and status register, follow the same definition as “BRIGHTNESS” 
Value 0 
Value 128 
Value 255 
 
 
 
 
• 
Operation   
U’ = U * saturation/128 
V’ = V * saturation/128 
  (U’, V’ =After applying the Saturation on the original image - U, V = Original color U and V) 
• 
Absolute values (%) = saturation* 100/128(%)