Maintenance Object Repair Procedures
9-977
ISDN-TRK (DS1 ISDN Trunk)
9
2221
2222
2223
2224
2225
2226
2222
2223
2224
2225
2226
ABORT
Internal system error. Follow recommendations for ABORT code 2012.
2227
ABORT
Could not allocate the necessary system resources to run this test. Follow
recommendations for ABORT code 2100.
recommendations for ABORT code 2100.
2042
FAIL
Comparison of data sent to data received indicates a loss of integrity on the
communications path.
communications path.
1. Take the trunk out of service and check the quality of the DS1 connection,
including the transmission facility and any external equipment such as
DAC s, CSU s, etc. Use test isdn-testcall and status isdn-testcall
commands to get the bit and block error rates.
DAC s, CSU s, etc. Use test isdn-testcall and status isdn-testcall
commands to get the bit and block error rates.
PASS
The test pattern was sent and received properly. If the synchronous test call
was performed (long test sequence), this indicates that the communications
path is operating properly. If the test isdn-testcall command was used, PASS
indicates only that the test call was established. Use the status isdn-testcall
command to get the bit and block error rates detected by the test. If the bit
and block error rates are not acceptable, perform a complete analysis of the
DS1 facility including the transmission facility and any external equipment
such as DAC s, CSU s, etc.
was performed (long test sequence), this indicates that the communications
path is operating properly. If the test isdn-testcall command was used, PASS
indicates only that the test call was established. Use the status isdn-testcall
command to get the bit and block error rates detected by the test. If the bit
and block error rates are not acceptable, perform a complete analysis of the
DS1 facility including the transmission facility and any external equipment
such as DAC s, CSU s, etc.