Lucent Technologies Release 7 User Manual
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1193
PE-BCHL (PRI Endpoint Port)
9
As with Test #256 (Service State Audit), a PASS simply means that an appropriate
message was composed and sent to the far-end terminal adapter. The ISDN
Specification allows up to 2 minutes for a reply. If a reply is not received within the
2 minute window, a protocol time-out violation will be recorded in the error log
against the associated signaling channel (ISDN-PRI Signaling Link Port, which is
listed in the Error Log as ISDN-LNK; the Error Type is 1).
message was composed and sent to the far-end terminal adapter. The ISDN
Specification allows up to 2 minutes for a reply. If a reply is not received within the
2 minute window, a protocol time-out violation will be recorded in the error log
against the associated signaling channel (ISDN-PRI Signaling Link Port, which is
listed in the Error Log as ISDN-LNK; the Error Type is 1).
Table 9-475.
TEST #257 Call State Audit Test
Error
Code
Code
Test
Result
Description/ Recommendation
1019
ABORT
An audit is already in progress.
1. Wait 2 minutes and try again.
1113
ABORT
The signaling link has failed, so the system cannot send any messages on
behalf of this port.
behalf of this port.
1. Check the results of Test #255 (Signaling Link State Check).
1116
ABORT
The port is in an out-of-service ISDN service state.
1. A call cannot be present if the port is in an ISDN out-of-service state, so a
call state audit would be inappropriate. No action necessary. (Use the
status pri-endpoint extension command to investigate the ISDN state of
the port).
status pri-endpoint extension command to investigate the ISDN state of
the port).
1700
ABORT
Rollabout video abort. The PRI terminal adapter associated with this PRI
endpoint extension is detached from the circuit pack. This is a normal abort
when the rollabout video feature is enabled.
endpoint extension is detached from the circuit pack. This is a normal abort
when the rollabout video feature is enabled.
1. Reconnect the disconnected PRI terminal adapter or disable the rollabout
video feature on this circuit pack. To do the latter, enter change ds1
UUCSS and set the field labeled ‘‘Alarm when PRI Endpoint Detached?’’
to ‘‘y.’’
UUCSS and set the field labeled ‘‘Alarm when PRI Endpoint Detached?’’
to ‘‘y.’’
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
FAIL
Internal system error
1. Retry the command at 1-minute intervals for a maximum of 5 times.
PASS
This switch sent a call state auditing message to the far-end terminal adapter
to verify the state of the call active on this port. If a call state mismatch is found,
then the call will be torn down within two minutes. If no call was active, then no
message was sent.
to verify the state of the call active on this port. If a call state mismatch is found,
then the call will be torn down within two minutes. If no call was active, then no
message was sent.
Continued on next page