DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1303
PNC-DUP (PNC Duplication) 
9
In the less common situation when the resolution of a fault on the standby 
renders it more healthy than a simultaneously faulted active PNC, the message 
will indicate the type and location of the 
improved component.
Once the interchange completes, the failed component will be on the standby 
PNC. A demand interchange can be requested in the presence or absence of 
standby PNC faults. The following sequence of actions can be observed during a 
fault-free interchange:
1. The Expansion Interfaces currently acting as archangels in the EPNs are 
deactivated as indicated by the yellow LEDs going from flashing to on 
solid.
2. The PPN EIs are interchanged as indicated by the new standby EI yellow 
LED off and the new active EI yellow LED on solid.
3. One by one the EPN EIs are interchanged as indicated by new standby EI 
yellow LED turning off and the new active EI yellow LED flashing (2 
seconds on, 200 milliseconds off). At this point the interchange is 
functionally complete.
4. The SNIs yellow LEDs are updated. so that the SNIs on the active SN have 
yellow LEDs on, while the standby SN’s SNIs yellow LEDs turn off.
Certain conditions may interfere with the normal execution of the interchange:
1. In a faulted spontaneous interchange it is possible the EPN/EPNs directly 
affected by the fault will be the last to interchange.
2. A user directly affected by the single fault instigating a PNC interchange 
can experience a momentary outage of voice path connectivity during the 
switch.
3. If faults exist on both the standby and active PNC, it is possible to have 
some EPNs go out of service while others are returned to service.
4. The new standby SNIs yellow LED my not be off due to a fault in the line of 
communication path to the standby SNIs. In a multi-fault interchange, 
LEDs on the new active SNIs may not be on for the same reason.
In any multifault situation, rely on status pnc to determine which is the active 
PNC.
PNC duplication informs Timing Synchronization maintenance when a PNC 
interchange has been completed and indicates which PNC is active. This will 
cause Synchronization to audit and insure that the primary source for 
synchronization of Tone-Clocks in each PN is supplied by a path associated with 
the active PNC.