Lucent Technologies Release 7 User Manual
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1326
PPP-PT (Control LAN Packet/Port)
9
Error Log Entries and Test to Clear Value
Notes:
a. Error Type 001: SCOTCH Synchronous Looparound Test (#1275) failed.
1. Test the port (test port UUCSSpp long).
2. Refer to SCOTCH Synchronous Looparound Test (#1275) repair
procedures.
b. Error Type 257: CLAN port detected overrun or underrun condition that
may indicate a hardware problem.
1. Test for hardware problem (test port UUCSSpp long).
Table 9-516.
CLAN Port Error Log Entries
Error Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test port UUCSSpp s
1 (a)
0
SCOTCH Sync
Looparound
Test (#1275)
Looparound
Test (#1275)
MINOR
ON
test port UUCSSpp l r 3
257 (b)
0
Under-run/Over-run
Error
Error
WARNING
OFF
513 (c)
0
PPP Link Failure
MINOR
OFF
769 (d)
0
Invalid Frame Error
WARNING
OFF
1281 (e)
0
Far-end disconnect
1537, 1538
(f)
(f)
See
note
note
Session Status Test
(#1286)
(#1286)
MINOR
OFF
1793-1920
(g)
(g)
See
note
note
Socket Failure
2305-2560
(h)
(h)
See
note
note
Session Down error
Session #s 1-256
Session #s 1-256
2561-2816
(h)
(h)
See
note
note
Session Down error
Session #s 257-512
Session #s 257-512
3329 (i)
35768
TCP/IP Ping Test
(#1281)
(#1281)
WARNING
OFF
3585 (j)
0-1
TDM Looparound
Test (#1285)
Test (#1285)
MAJOR
ON
test port UUCSSpp l r 3
Continued on next page