DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1668
TBRI-BD (TN2185 ISDN Trunk-Side BRI) 
9
Notes:
a. The circuit pack stopped functioning or is physically removed from the 
system.
NOTE:
This alarm logs approximately 11 minutes after removing the circuit 
pack and/or the SAKI Sanity Test (#53) fails.
If the circuit pack is not in the system, insert a circuit pack in the same slot 
as the error indicates. See note (g).
b. Transient communication problems between the switch and this circuit 
pack. Execute the test board UUCSS command and refer to the repair 
procedures for the Control Channel Loop Around Test (#52).
c. On-board hardware failure. Aux data values correspond to the following 
detected errors:
1795 (i)
46085
MINOR
ON
2305 (j)
46104
None
ON
2306 (i)
46081
None
ON
3330 (j)
46083
MINOR
OFF
3586 (k)
MINOR
OFF
3840(l)
4096
to
4101
3842 (m)
46095
3843 (n)
46097
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the 
appropriate test description and follow the recommended procedures.
4352
External RAM error
4353
Internal RAM error
4355
ROM Checksum error
4357
Instruction set error
Table 9-625.
TBRI-BD Error Log Entries  — Continued
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
Continued on next page