Maintenance Object Repair Procedures 
9-1723
TDM-CLK (TDM Bus Clock) 
9
b. The indicated Tone-Clock circuit pack has been made unavailable via the 
busyout tone-clock UUC command. It only applies to systems which 
have the High or Critical Reliability Option administered, because only a 
standby Tone-Clock circuit pack may be made busy by that command. To 
resolve this error, execute the release tone-clock UUC command for the 
alarmed circuit pack.
c. This error type indicates that the circuit pack has been removed or has 
been insane for more than 11-minutes. To clear the error, reinsert or 
replace the circuit pack.
d. The Tone-Clock circuit pack in the PPN is not a TN780 while a Stratum 3 
synchronization is administered. Replace the Tone-Clock in the PPN with a 
TN780, or change synchronization administration to Stratum 4 if a Stratum 
3 clock is not being used.
e. The tone-clock has reported an out-of-lock condition. A aux value of 1 
indicates this error is an out-of-lock with the primary reference. A aux 
value of 2 indicates this error is an out-of-lock with the secondary 
reference. It could not lock onto the frequency of that synchronization 
reference. This will lead to a change in the synchronization reference if the 
condition continues.
f. The Tone-Clock circuit pack may be defective, however it may be a 
software failure that can be corrected by testing.
1. Check to see if the board is duplicated (list cabinet and status 
port-network) on the affected port network.
2. If the board is not duplicated, use test tone UUCSS long to resolve 
the errors. The long test resets the board and is required to reload 
on-board RAM associated with the TN2182’s DSPs. The effect is 
that tone detectors are taken out of service momentarily and tones 
are removed from the TDM bus for about 10 seconds, meaning that 
no dial tone or touch tones are available during this interval. This 
will probably not affect calls in progress, but could cause a call 
origination to abort or a user not to get dial tone when going off 
hook.
3. If all tests pass and the alarm does not resolve, retest with test tone 
UUCSS long clear.
4. If the test passes, terminate the repair process. If the test fails, 
replace the circuit pack at the customer’s convenience.
5. If this error was logged against the standby Tone-Clock, and if the 
Aux Data value was 18369, SYNC (Synchronization) maintenance 
acts on this error. No corrective action is required. For any other 
Aux Data, go to the next step.
6. If the board is duplicated, switch to the standby side (set tone).
7. Test the alarmed board (test tone UUCSS long). This resets the 
board and is required to reload on-board RAM associated with the 
TN2182’s DSPs.