Maintenance Object Repair Procedures
9-1728
TDM-CLK (TDM Bus Clock)
9
1
FAIL
This error means the Tone-Clock circuit pack framing verification firmware
reports an error in the clock synchronization signal coming into this Port
Network.
reports an error in the clock synchronization signal coming into this Port
Network.
1. If the Tone-Clock circuit pack reporting the problem is a master clock, then
the system synchronization reference is providing a bad timing source.
Refer to SYNC (Synchronization) or STRAT-3 (Stratum 3 Clock)
Maintenance documentation to change the system synchronization
reference.
Refer to SYNC (Synchronization) or STRAT-3 (Stratum 3 Clock)
Maintenance documentation to change the system synchronization
reference.
2. If the Tone-Clock circuit pack is a slave clock, then the EI to which it is
listening is providing a bad timing source. Follow the diagnostic
procedures specified for TDM-CLK Error Code 2305.
procedures specified for TDM-CLK Error Code 2305.
3. If no problem can be found with the incoming synchronization signal,
Circuit Pack in the TONE-BD section.
2
FAIL
This error indicates that Tone-Clock circuit pack has inaccurately detected loss
of signal on the incoming synchronization timing source.
of signal on the incoming synchronization timing source.
4
or
8
or
8
FAIL
The local oscillator on the Tone-Clock circuit pack has failed.
16
or
32
or
32
FAIL
The circuitry on the Tone-Clock circuit pack used to detect synchronization
timing errors has failed.
timing errors has failed.
1. Errors 2, 4, 8, 16, and 32 indicate that there is poor synchronization
between port networks and external facilities. It may be noticeable to the
customer in the form of errors in data communications. The Tone-Clock
circuit pack is defective. See
customer in the form of errors in data communications. The Tone-Clock
circuit pack is defective. See
in the TONE-BD section.
64
FAIL
This message is only sent when an uplink message has reported the loss of
valid synchronization timing information coming into this Port Network. It has
been reported in TDM-CLK Error Log entries; one or more of 1025, 1281, 1537,
2049 and 2305.
valid synchronization timing information coming into this Port Network. It has
been reported in TDM-CLK Error Log entries; one or more of 1025, 1281, 1537,
2049 and 2305.
1. Resolve the errors indicated. No separate corrective action is required.
Table 9-646.
TEST #148 TDM Bus Clock Circuit Status
Inquiry Test — Continued
Error
Code
Code
Test
Result
Description/ Recommendation
Continued on next page