8-127
list configuration 
8
list configuration
list configuration hardware-group [print | schedule]
NOTE:
The list configuration software-version command is discussed 
separately under its own heading.
Hardware configuration reports list, for each circuit pack in the group specified, 
the type, code, suffix, and vintage of the requested circuit packs as installed in 
the switch, and all ports assigned to the circuit pack.
Parameters
Enter one of the following hardware groups.
all—Specifies the display of all circuit packs administered and/or 
physically inserted in port, switch node and control carriers on the entire 
system.
board 
UUCSS
Specifies the display of all assigned ports on the circuit 
pack specified by cabinet, carrier and slot.
carrier 
c
Specifies the display of all circuit packs and assigned ports on 
a specified carrier.
control—Specifies the display of all circuit packs located in the control 
complex.
Interface Link
Identifies the physical link carrying this processor (virtual) 
channel. Links numbered 1 through (4 times the number of PI 
circuit packs) for the si model can be either x.25 or tcp/ip. The 
rest of the links (up to 25) must be tcp/ip.
Interface Chan
Identifies the BX.25 virtual channel number or the TCP/IP listen 
port channel to carry this processor (virtual) channel. The channel 
number 0 means any port can be used. Valid entries for link type 
x.25 are 1-64; for Ethernet or ppp, 05000-64500.
Destination Node
Identifies the switch or adjunct at the far end of this link. Enter an 
adjunct name, switch name, far end IP address, node ID, or leave 
blank (default) for services local to this switch.
Destination Port
Identifies the port number of the destination. The number 0 means 
any port can be used. Valid entries are 0 (default), 5000-64500.