Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-12
ADM-CONN (Administered Connection) 
9
For all ADM-CONN errors:
All of the above errors have no specific test associated with them and, except for 
errors 17 and 127, are valid only for administered connections established over 
ISDN-PRI facilities. Error 127 is valid for administered connections established 
over non-ISDN facilities or between two endpoints on the same switch.
Notes:
a. These errors are typically associated with administration problems and are 
not expected to be of a temporary nature. The administered connection is 
not retried and the failure is alarmed immediately. The alarm threshold 
specified by the customer is ignored.
b. The address of the destination endpoint is: an unassigned number (1), 
has an invalid number format (28), or is restricted from terminating calls 
due to Class of Restriction (‘‘Access Denied’’). Verify that the destination 
address is correct and that the destination endpoint is administered. The 
destination endpoint is not administered on the switch where this error is 
logged.
c. A request has been made to use a transit network or common carrier that 
cannot be accessed. Check the routing pattern used by this administered 
connection and verify that the inter-exchange carrier specified is correct.
16 (a)
Any
None
Any
OFF
None
17 (e)
Any
None
Any
OFF
None
18, or 102 (f)
Any
None
Any
OFF
None
22 (a,g)
Any
None
Any
OFF
None
34,42,44, or 58 (h)
Any
None
Any
OFF
None
38, or 41 (i)
Any
None
Any
OFF
None
43, or 81 
Any
None
Any
OFF
None
50 (a)
Any
None
Any
OFF
None
52 (a)
Any
None
Any
OFF
None
54 Any
None
Any
OFF
None
65,66, or 69 (a)
Any
None
Any
OFF
None
82
Any
None
Any
OFF
None
88 (a)
Any
None
Any
OFF
None
91,95,96,97,98,99,1
00, or 111
Any
None
Any
OFF
None
Table 9-5. Administered Connection Error Log Entries  — Continued
Error Type
Aux 
Data
Associated 
Test
Alarm 
Level
On/Off 
Board
Test to Clear 
Value
Continued on next page