ADX8D-PT (AUDIX Digital Port) 
9
7
FAIL
Conference Test failed on the primary channel. Some users may not notice 
a disruption in service. In extreme cases, the conferencing feature may 
not work at all.
14
FAIL
The primary voice channel is not transmitting properly. User impact may 
range from no noticeable effect to loss of use of this port.
15
FAIL
The control channel between the processor and DEFINITY AUDIX circuit 
pack is not transmitting properly. User impact may range from no 
noticeable effect to loss of use of this port. This failure could also be 
disruptive to other users.
16
FAIL
The secondary voice channel is not transmitting properly. User impact 
may range from no noticeable effect to loss of use of this port.
None
FAIL
The test failed for reasons external to the DEFINITY AUDIX circuit pack.
1. Run circuit pack tests to check the Tone Generator circuit pack and 
the Tone Detector circuit pack by using the test board UUCSS s 
command.
2. Resolve any problems that are detected on the Tone Generator circuit 
pack or Tone Detector circuit pack.
3. If the Tone Generator and Tone Detector circuit packs are functioning 
properly, and if the test still fails, replace the DEFINITY AUDIX circuit 
pack (see precaution at the beginning of this section).
PASS
Voice and Control Channel Local Loop test passed. All channels are 
transmitting properly.
1. To be sure that this is not an intermittent problem, repeat this test up to 
10 times and see if it continues to pass.
2. If complaints still exist, examine the connections.