DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-250
ATM-SYNC (ATM Synchronization) 
9
Notes:
a. Error Type 1: problem with the primary DS1 reference. It is cleared when 
the primary reference is restored. The following steps should give an 
indication of the source of the problem:
1. Check if the primary DS1 interface circuit pack is inserted in the 
carrier with the list configuration board UUCSS command.
2. Verify that the administered primary reference matches the DS1 
reference from the network synchronization plan.
3. Test the primary DS1 interface circuit pack with the test board 
UUCSS long command. Check the Error Log for DS1-BD or 
UDS1-BD errors and refer to the DS1-BD or UDS1-BD (DS1 
Interface Circuit Pack or UDS1 Interface Circuit Pack) Maintenance 
documentation to resolve any errors associated with the primary 
DS1 (DS1 or UDS1) interface circuit pack. If the only errors against 
DS1-BD or UDS1-BD are slip errors, then follow the procedures 
described in the troubleshooting section above. If no errors are 
listed in the Error Log for the primary DS1 interface circuit pack, 
continue with the following steps.
4. Test the active Tone-Clock circuit pack in the master port network 
with the test tone-clock UUC long command. Check the Error Log 
for TDM-CLK errors and verify that TDM Bus Clock Test #148 (TDM 
Bus Clock Circuit Status Inquiry Test) passes successfully. If Test 
#148 fails with an Error Code 2 through 32, refer to the TDM-CLK 
(TDM Bus Clock) Maintenance documentation to resolve the 
problem.
b. Error Type 257: problem with the secondary DS1 reference. It is cleared 
when the secondary reference is restored. Refer to note (a) to resolve this 
error substituting secondary for primary in the preceding resolution 
steps.
c. Error Type 513: the ATM switch clock is inferred to be providing the timing 
source for the system. The primary and secondary (if administered) are 
not providing a valid timing signal. Investigate errors 1 and 257 to resolve 
this error.
d. Error Type 1537: over half of the DS1s that are administered with slip 
detection enabled through the 
Slip Detection?
 field set to are 
experiencing slips.
e. Error Type 1793: inferred excessive switching of system synchronization 
references has occurred. When this error occurs, it is inferred that the ATM 
switch clock has become the synchronization reference for the system.
1. Check for timing loops and resolve any loops that exist.
2. Test the active Tone-Clock circuit pack in the master port network 
with the test tone-clock UUC long command. Check the Error Log 
for TDM-CLK errors and verify that TDM Bus Clock Test #148 (TDM