Panasonic WV-SW350 Series User Manual

Page of 220
4   Action at an alarm occurrence
The alarm action (camera action at an alarm occurrence) will be performed when the following alarms occur.
4.1  Alarm type
Terminal alarm 
SW355
SW355
 
SW352
SW352
 
SF346
SF346
 
SF342
SF342
 
SF335
SF335
 
SW316L
SW316L
 
SW316
SW316
 
SP306
SP306
 
SP305
SP305
SP302
SP302
 
NP502
NP502
: When connecting an alarm device such as a sensor to the alarm input terminal of the
camera, the alarm action will be performed when the connected alarm device is activated.
VMD alarm: When motion is detected in the set VMD area, the alarm action will be performed.
*VMD stands for “Video Motion Detection”.
Command alarm: When a Panasonic alarm protocol is received from the connected device via a network,
the alarm action will be performed.
4.2  Action at an alarm occurrence
Display the alarm occurrence indication button on the “Live” page
The alarm occurrence indication button will be displayed on the “Live” page at an alarm occurrence.
(
IMPORTANT
When “Polling(30s)” is selected for “Alarm status update mode” (
indication button will be refreshed in 30-second intervals. For this reason, it may take a maximum of
30 seconds until the alarm occurrence indication button is displayed on the “Live” page at an alarm
occurrence.
Notify of alarm occurrences to the device connected to the alarm connector
(SW355, SW352, SF346, SF342, SF336, SF335, SF332, SW316L, SW316,
SP306, SP305, SP302, NP502, NW502S)
It is possible to output signals from the alarm output terminal of the camera and sound the buzzer when an
alarm occurs. The settings for the alarm output can be configured in the “Alarm output terminal setup” section
of the [Alarm] tab of the “Alarm” page. (
Save images on the SD memory card (SW355, SW352, SF346, SF342, SF336,
SF335, SF332, SW316L, SW316, SP306, SP305, SP302, SW155, SW152,
NP502, NW502S, SW115)
When an alarm occurs, images (JPEG/H.264) will be saved on the SD memory card. The settings to save
images on the SD memory card can be configured on the [SD memory card] tab (
page and the [Alarm] tab of the “Alarm” page. (
Transmit an image onto a server automatically
An alarm image can be transmitted at an alarm occurrence to the server designated in advance. The settings
required to transmit an alarm image to a server can be configured in the “Alarm image” section on the
[Alarm] tab of the “Alarm” page (
28
Operating Instructions
4 Action at an alarm occurrence