3   Action at an alarm occurrence
The alarm action (camera action at an alarm occurrence) will be performed when the following alarms occur.
3.1  Alarm type
Terminal alarm 
VT164W
VT164W
 
VT164
VT164
: When connecting an alarm device such as a sensor to the EXT I/O
connectors 1-3 of the camera, the alarm action will be performed when the connected alarm device is
activated.
Body heat sensor 
VT164W
VT164W
 
VT164
VT164
: When a temperature difference is detected in the sensor's detection
area, the alarm action will be performed.
VMD alarm: When motion is detected in the set VMD area, the alarm action will be performed.
*VMD stands for “Video Motion Detection”.
Command alarm: When a Panasonic alarm protocol is received from the connected device via a network,
the alarm action will be performed.
3.2  Action at an alarm occurrence
Display the alarm occurrence indication button on the “Live” page
The alarm occurrence indication button will be displayed on the “Live” page at an alarm occurrence. (
®
VT164W
VT164W
 
VT164
VT164
VP104W
VP104W
 
VP104
VP104
 
VP101
VP101
IMPORTANT
When “Polling(30s)” is selected for “Alarm status update mode” (
indication button will be refreshed in 30-second intervals. For this reason, it may take a maximum of
30 seconds until the alarm occurrence indication button is displayed on the “Live” page at an alarm
occurrence.
Notify of alarm occurrences to the device connected to the alarm connector
It is possible to output signals from the alarm connector on the rear of the camera and sound the buzzer when
an alarm occurs. The settings for the alarm output can be configured in the “Alarm output terminal setup”
section of the [Alarm] tab of the “Alarm” page. (
Transmit an image onto a server automatically
An alarm image can be transmitted at an alarm occurrence to the server designated in advance. The settings
required to transmit an alarm image to a server can be configured in the “Alarm image” section on the
[Alarm] tab of the “Alarm” page (
Notify of alarm occurrences by E-mail
Alarm E-mail (alarm occurrence notification) can be sent at an alarm occurrence to the E-mail addresses
registered in advance. Up to 4 addresses can be registered as recipients of the alarm E-mail. An alarm image
(still picture) can be sent with the alarm E-mail as an attached file. The settings for alarm E-mail can be
configured in the “E-mail notification” section on the [Notification] tab of the [Alarm] page (
the [E-mail] tab of the “Server” page (
30
Operating Instructions
3 Action at an alarm occurrence