Pelco EH8104 User Manual

Page of 4
®
EH25/8104ORKIT
O-Ring Replacement Kit for
EH2500 Series Dust-Tight and
EH8104 Series
Pressurized Camera Enclosures
Installation/Operation Manual
C1953M (11/98)
Pelco • 3500 Pelco Way • Clovis, CA 93612-5699 • USA • www.pelco.com
In North America and Canada: Tel (800) 289-9100 • FAX (800) 289-9150
International Customers: Tel (1-559) 292-1981 or FAX (1-559) 348-1120
The EH25/8104ORKIT contains two O-rings (one will be used for the rear plate
seal only, the second is a spare), a tube of O-ring lubricant, and two bags of desic-
cant.
This O-ring kit installation instruction applies to the EH2500 and EH8104 Series
enclosures.
Pelco does not supply basic tools needed for the installation process. The following
tools are recommended:
5/64-inch Allen wrench (for EH2500 Series only)
Flat screwdriver
EH8000RKIT recharge kit (for EH8104 Series only)
Assorted wrenches (for EH8104 Series only)
O-RING REPLACEMENT (EH2500 Series Enclosures)
1.
Turn off power to the enclosure.
2.
Remove the two screws that attach the rear plate to the enclosure.
3.
Disconnect the video and electrical cables inside the enclosure.
4.
Remove the desiccant bags inside the enclosure and replace them with the
two bags from the kit.
5.
Remove the O-ring from the groove in the enclosure rear plate and discard.
Be careful not to damage or score the O-ring groove. Clean the O-ring groove
thoroughly.