Preparing the Site for the VCN Access Concentrator
23
Installing the VCN
Access Point
Punch-down Block
with a Patch Panel
To install the VCN AP punch-down block when there is a patch panel, 
perform the following steps:
Select the wire pairs according to their position in the RJ-11 telephone 
connector in the rear of the VCN AP. The two outside wires comprise the 
outer wire pair and the two inside wires comprise the inner wire pair, as 
shown in 
.
Where there is only one telephone line in a room, the two wires are 
connected to the inner wire pair of the phone connector shown in 
 and 
. The outer wire pair of the phone connector is not 
used.
The inner wire pair carries both voice and digital date.
The outer wire pair carries only voice.
Figure 7   VCN Access Point Rear Pane
Figure 8   The Four Wires of the Telephone Cable
Disconnect the punch-down Krone connector for the inner wire pair from 
the PBX punch-down block.
The outer wire pair remains connected to the PBX punch-down block 
since it will not carry data.
P H O N E
L IN E
D C -IN
Inner wire pair
Outer wire pair