3com DSA-3CV1100-02 User Manual

Page of 158
Installing the VCN Access Concentrator
27
Figure 12   VCN Access Point Punch-down Block Installation without a Patch 
Pane
Repeat 
 through 
 for up to 24 telephone lines.
The VCN AP and PBX punch-down blocks must each have an RJ-21 
connector.
Installing the VCN 
Access 
Concentrator
Before installing the VCN AC make sure that:
The unit is accessible and can be connected easily.
Cabling is away from:
Sources of electrical noise such as radios, transmitters and 
broadband amplifiers
Power lines and fluorescent lighting fixtures
Water or moisture cannot enter the case of the unit.
V C N A P
R o om
B as em ent
W ire  p air  not
co nne cte d 
to   V C N A P  
W ire   p air
co nne cte d 
to   V C N A P  
P un ch-D ow n   B loc ks
P B X
V C N A P  p un ch-dow n
blo ck
P B X   pu nch -d ow n
blo ck
E xte nsio n 2
E xte nsio n 1
E xt.  1
+   D ata
E xt.  2
Note: If there is only one 
extension in the room, 
the wires for the second 
extension are not used 
and not connected to the 
PBX punch down block.